three wavelength laser hair elimination equipment

Store the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG equipment capabilities three wavelengths (755, 808, 1064nm) for pain-free hair removal.
2-in-1 Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Machine
Accomplish Qualified-quality effects with the Soprano Titanium Ice Platinum, a powerful two-in-one process combining three-wavelength diode laser technological know-how for pain-free hair removal along with a Q-Switched ND:YAG laser for tattoo removing and skin rejuvenation. Equipped that has a 4000W high-energy motor and 5-amount adjustable cooling know-how, this CE-Licensed equipment gives Harmless, productive, and permanent benefits for all pores and skin kinds and overall body areas.

Hair Removal: Triple wavelength (755nm, 808nm, 1064nm) for all skin tones
Skin Correction: Q-Switched ND:YAG for tattoo elimination and carbon peeling
Comfort and ease: five-Amount adjustable cooling system to get a painless expertise
Electricity: 4000W significant-Electricity density with German Diode Arrays

Vital Characteristics
three-Wavelength Diode Technological innovation: Integrates 755nm (Alexandrite), 808nm (Speed), and 1064nm (YAG) wavelengths into an individual applicator to target different hair depths and constructions at the same time.
Dual-Purpose System: A real 2-in-one workstation that includes a focused Diode laser for lasting hair reduction plus a Q-Switched ND:YAG laser for pigmented lesion remedy and tattoo removal.
Highly developed 5-Level Cooling: Functions the “Titanium Ice” five-level adjustable cooling technological know-how that keeps the sapphire idea at an optimum temperature, making sure the treatment method remains cozy and pain-free.
Substantial Output Overall performance: Pushed by a large 4000W energy provide and German-imported Diode arrays, offering around 2000mj Electrical power density for rapidly and productive scientific benefits.
Substantial Touchscreen Interface: Equipped that has a higher-definition interactive Exhibit for precise Management over Vitality degrees, pulse frequency, and cooling intensity across diverse treatment modes.
Compatibility & Greatest Use
Whole Body Application: Safe and sound and efficient for use about the facial area (upper lip, chin), underarms, bikini line, arms, legs, back again, and chest.
All Pores and skin Styles: The triple wavelength program is built to get the job done effectively on all skin tones (Fitzpatrick scales I-VI) and hair shades, website together with great and light hair.
Skin Rejuvenation: Make use of the ND:YAG cope with While using the black doll (carbon) tip for deep pore cleaning, pores and skin whitening, and anti-getting older treatment options.
Tattoo & Pigment Elimination: Focus on darkish and coloured inks precisely using the Q-Switch frequency for non-invasive removal of tattoos and freckles.
Installation Ideas
Drinking water Cooling Set up: This substantial-electricity laser involves distilled h2o for its cooling procedure; make sure the drinking water tank is crammed into the proposed amount right before powering over the equipment for The 1st time.
Tackle Relationship: Thoroughly align the pins of your laser handles check here While using the equipment ports and protected the locking system to make certain steady signal and cooling fluid transmission.
Voltage Verification: The machine supports 110V and 220V; ensure your power outlet matches the precise voltage configurations on the device to click here stop electrical harm.
Parameter Calibration: For new buyers, it is usually recommended to get more info start out therapies at the lowest energy configurations and little by little enhance check here depending on the client’s pores and skin sensitivity and opinions.
Solution Specifications
Manufacturer Title emszero
Model Number Titanium two-in-1 (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Power Output 4000W
Electricity Density Approximately 2000mj (Adjustable)
Cooling Degree five Stages Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, 50/60Hz
Packing Record
1 x Soprano Titanium two-in-one Primary Console (4000W)
one x 3-Wavelength Diode Laser Handle
one x Q-Switch ND:YAG Laser Tackle
3 x Specialized ND:YAG Guidelines (532nm, 1064nm, 1320nm)
1 x Ability Cable & Foot Pedal
1 x User Guide & Protective Goggles Established

Warnings & Security Notes
Eye Protection: Often wear the furnished laser-security goggles during Procedure to prevent lasting eye injury from stray laser reflections.
Never Run Dry: Do not run the machine with no filling it with distilled water; jogging the laser with no performing cooling loop will lead to speedy inner components failure.
Contraindications: Usually do not use this machine on regions with open up wounds, Energetic bacterial infections, or on individuals who are Expecting or have light-weight-sensitive professional medical situations.
Cooling Routine maintenance: Change the distilled drinking water every three months to ensure The interior pump and laser arrays keep on being free of mineral buildup and overheating.

Leave a Reply

Your email address will not be published. Required fields are marked *